Page 181 - 温州西卡电器有限公司(WENZHOU XIKA ELECTRICAL CO.,LTD.)
P. 181

Wenzhou Xika
           Application
                                                                                                Electrical Co.,Ltd.

                                                          > Color Identification
           EPR insulated and halogen-free thermoplastic compound
           sheathed power and auxiliary control cables for the sup-  2 Core + Earth(Red/Black)
           ply of electric energy. Special for installations shere fire  3 Core + Earth(Red/Black/Green)
                                                          4 Core + Earth(Red/Yellow/Blue/Black)
           and emissions of smoke and toxic fumes create a poten-
                                                          Sheath(Black/White/Red/Orange)
           tial threat. Not suitable for use in water.
                                                              Nr.of    Diameter of  Insulation  Diameter  Final
           XLPE insulated, LSOH bedded, steel round wires  conductro X  conductor  thicknss  earth wire  diameter
                                                           sect.(sqmm)   (mm)       (mm)       (mm)      (mm)
           armoured and LSOH sheathed power and auxiliary con-
                                                              2 x 1       1.5        0.6       1.15       8.0
           trol cables for the supply of electrical energy.Special for
                                                              3 x 1       1.15       0.6       1.15       8.3
           installation where fire and the emission of smoke and toxic
                                                              4 x 1       1.15       0.6       1.15       8.9
           fumes create a serious potential threat.
                                                             2 x 1.5      1.40       0.6       1.15       8.4
                                                             3 x 1.5      1.40       0.6       1.15       8.9
           FLAME-X 950 helps to protect human life in the event of fire in  4 x 1.5  1.40  0.6  1.15      9.5
           public buildings or industrial installations, e.g. in industrials  2 x 2.5  1.80  0.6  1.40    9.2
           complexes, power stations, public buildings, hotels, underground
           railway systems, hospitals, airports, data processing centrex,  3 x 2.5  1.80  0.6  1.40       9.7
           emergency power suply and alarm system etc. Suitable for fixed  4 x 2.5  1.80  0.6  1.40      10.5
           installation in dry and moist rooms as well as for outdoor applica-
           tion ,not however direct installation in the application, not how-
           ever direct installation in the application, not however direct in-  > Fireflex Cables
           stallation in the earth or in water.
           Performance under fire conditions: Insulation integrity for 180  Voltage rating(V): 300,450/450 and 600/1000
           minutes-IEC 60331-21; Flame propagation:       Standed Conductors to BS 6360 class 1,2 and 5
           EN 50266-2-2, IEC 60332-3-22-Cat.A
                                                          Fire Flex Cables to BS 5839-1:2002 par 26.2d
                                                          BS 6387C    Resistanct to fire alone at 3 hours at 950 C.
                                                                                             o
                                                                                        o
           Halogen-free lo smoke fire resistant power cables are designed  BS 6387W   Resistanct to fire & water at 650 C for 15 min. With fire & water.
                                                                                                o
           for fixed installation both in ordinary and damp environments.  BS 6387Z    Resistanct to fire with mechanical shock 950 C for 15
           They can also be used on an inflammable surface and in envi-  min, with 30 sec, hammers blows.
           ronment with fire hazards where maintenance of circuit integrity  BS 6425;Part 1   Acid gas emission
           during and after a maintenance of circuit integrity during and af-  BS 4066;Part 1   Flame progogation
           ter a frie is required.
                                                          BS 4066;Part 3   Flame progogation
           Perfirnabce under fire condition:Insulation integrity for 180 min-
                                                          IEC 60331   Resistance to fire 3 hours at 750 C.
                                                                                        0
           uted-IEC 60331-21; Flame propagation: En 50266-2-2, IEC
                                                          BS 7622/EN50621-1   Smoke Emission
           60332-3-22-Cat.A
                                                          IEC 7622   Smoke Emission
                                                          IEC60754;Part 1   Acid gas emission
           Fire resistant security cables for installation everywhere where  IEC 60332-3   Flame propogation
                                                          BS 6360   High conductivity annealed copper conductor
           high safety requirements have a special significance e.g., in in-
                                                          BS 7629   Cable construction
           dustrials complexes, power station, public buildings, hotels, un-
                                                          EN 50200 PH 30   Functionality to fire-30 min
           derground railway systems, hospitals, airport etc. Suitable for fixed
           installation in dry and moist rooms as well as for outdoor  > Standard
           application, not however direct installation in the earth or in water.
           FE180: Installation integrity for 180 minutes- DIN VDE 0472/814  IEC 331      Fire-resistance characteristics of electric cables
                                                          IEC 332-1   Flame-retardant characteristics of electric cables
           (IEC 60331-21).E30 and E90:Functionality for electrical cable
                                                          IEC 332-3   Test on electric cables under fire conditions IEC754-1
           system for minimum 30 minuted (E30)and 90 minutes(E90)-DIN
                                                          IEEE 383    IEEE std for type test of class 1E Electric cables,
           4102-12.Flame propagation: DIN VDE 0472-804 C(IEC 60332-
                                                                  fieldsplices, and connections for nuclear power
           3)
                                                                  generation station. Verticaltray flame test.
                                                          DEF STD 61-12(Part 18)   Wires, cords and cable,eletricmetricunits.
                                                                            Part 18:Equipment wires limited fire hazard.
                                                          BS 6387  Performance requirements for cable required to maintain
                                                                 circuit integrity under fire conditions.
                                                                                                                   www.seicae.com
                                                          BS 8434-1 2003  Functionality to fire 30 min frie, mechanical shock
                                                                      and later test described in clause
                                                                      26.2d of BS 5839-1:2002
                                                                                                            >F 169