TEMPERATURE AND
HUMIDITY CONTROLLER SERIES YINGMING POWER
YM-WK-G (TH) temperature controller
1FEFTUBM 5FNQFSBUVSF 4FOTPS
The main function
One way temperature control, the control value is fixed. Ensure that the
ambient temperature meets the working standards and is divided into a
"$ 7 heating type and a cooling type.
);
5FNQFSBUVSF MPBE /FVUSBM MJOF 1IBTF MJOF
&NCFEEFE 5FNQFSBUVSF 4FOTPS
Technical characteristics
◆ Power supply: AC220V±10% 50Hz;
◆ Temperature control: 5 ℃ heating mode, 15 ℃ reset cooling type 40 ℃
action, 30℃ reset;
"$ 7
)[ ◆ Output: resistive AC220V/5A (active);
Note: This figure is for reference only. 5FNQFSBUVSF MPBE /FVUSBM MJOF 1IBTF MJOF
Please refer to the actual product for the ◆ Dimensions: 48 × 48 × 78mm . 3
specific wiring!
YM-N2K(TH) dual dew point controller
1FEFTUBM The main function
$POEFOTBUJPO TFOTPS * $POEFOTBUJPO TFOTPS ē
Two-way condensation control, when the temperature is too high or there
will be condensation, start the load and destroy the conditions that cause
condensation. It can control two different environments at the same time
or achieve dual control for one environment.
"$ 7
);
$POEFOTBUJPO MPBE * $POEFOTBUJPO MPBE ē /FVUSBM MJOF 1IBTF MJOF
Technical characteristics
&NCFEEFE
$POEFOTBUJPO TFOTPS $POEFOTBUJPO TFOTPS ◆ Power supply: AC220V±10% 50Hz;
◆ Temperature control: 88% RH ± 5% RH (at 20 ℃ );
◆ Response speed: typical value ≤ 5s;
◆ Load control: manual / automatic conversion;
"$ 7 ◆ Output: resistive AC220V/5A (active);
)[
$POEFOTBUJPO MPBE * $POEFOTBUJPO MPBE ē /FVUSBM MJOF 1IBTF MJOF ◆ Dimensions: 48 × 48 × 78mm . 3
Note: This figure is for reference only. Please refer to the actual product for the specific
wiring!
YM-NWK(TH) temperature and humidity controller YM-WSK-G(TH) temperature and humidity controller
The main function
1FEFTUBM
$POEFOTBUJPO TFOTPS 5FNQFSBUVSF 4FOTPS Condensation control unit, a temperature control unit, can control the
temperature and humidity of the environment in real time, automatically
start the load, ensure that the temperature index meets the working
standard, and at the same time effectively prevent the condensation from
occurring, and separate the heating type and cooling type.
"$ 7
);
$POEFOTBUJPO MPBE 5FNQFSBUVSF MPBE /FVUSBM MJOF 1IBTF MJOF Technical characteristics
&NCFEEFE
$POEFOTBUJPO TFOTPS 5FNQFSBUVSF 4FOTPS ◆ Power supply: AC220V±10% 50Hz;
◆ Condensation start control: 88% RH ± 5% RH (at 20 ° C);
◆ Response speed: typical value ≤ 5s;
◆ Control range: The control value is fixed according to the user's
requirements. The factory setting (-30-70 ℃ ) is 4-6℃ .
"$ 7 ◆ Load control: manual / automatic conversion;
)[
$POEFOTBUJPO MPBE 5FNQFSBUVSF MPBE /FVUSBM MJOF 1IBTF MJOF ◆ Output: Resistive AC220V/5A×2 (active);
◆ Dimensions: 48×48×78mm . 3
Note: This figure is for reference only.
Please refer to the actual product for the
specific wiring!