Page 16 - 浙江中盛电力设备有限公司
P. 16

S11


                                                                                              系列油浸式变压器
                                                                                 Series of oil-immersed transformer


           S11-M 系列 20kV 级三相双绕组无励磁调压配电变压器
           S11 - M series 20 kv three-phase double-winding non-field excitation changer distribution transformer

                                      电压组合及分接范围
            额定容量                Voltage Combinationand Tap range  联结组标号       空载损耗     负载损耗     空载电流     短路阻抗
            Rated capacity    高压        高压分接范围           低压         Vector    No-load  Load loss  No-load  Short circuit
            (kVA)         High pressure  High pressure tap   Low pressure  Group Symbol  loss(W)  (W)  current  impedance
                                                                                                  (%)
                                                                                                           (%)
                              (kV)       range (% )     (kV)
            30                                                                 100     690/660    2.1
            50                                                                 130     1010/960    2
            63                                                                 150    1200/1150   1.9
            80                                                                 180    1440/1370   1.8
            100                                                                200    1730/1650   1.6
            125                                                                240    2080/1980   1.5
                                                                                                           5.5
            160                                                                280    2540/2420   1.4
            200                                                                340    3000/2860   1.3
            250               20                                    Dyn11      400    3520/3350  1.20
                                           ±5%
            315               22         ±2×2.5%         0.4        Yzn11      480    4210/4010   1.10
            400               24                                    Yyno       570    4970/4730  1.00
            500                                                                680    5940/5660  1.00
            630                                                                810      6820     0.90
            800                                                                980      8250     0.80
            1000                                                               1150     11330    0.70
            1250                                                               1380     13200    0.70      6.0
            1600                                                               1650     15950    0.60
            2000                                                               1950     19140    0.60
            2500                                                               2340     22220    0.50


           S11 系列 35kV 级三相双绕组无励磁调压配电变压器
           S11 series 35 kv three-phase double-winding non-field excitation changer distribution transformer

                                   电压组合及分接范围
            额定容量            Voltage Combinationand Tap range  联结组标号       空载损耗       负载损耗      空载电流      短路阻抗
            Rated capacity  高压       高压分接范围         低压         Vector     No-load   Load loss  No-load  Short circuit
            (kVA)       High pressure  High pressure  Low pressure  Group Symbol  loss(W)  (W)  current  impedance
                                                                                                           (%)
                                                                                                 (%)
                            (kV)     tap range (% )  (kV)
            50                                                              160     1200/1140    1.30
            100                                                             230     2010/1910    1.10
            125                                                             270     2370/2260    1.10
            160                                                             280     2820/2680    1.00
            200                                                             340     3320/3160    1.00
            250                                                             400     3950/3760    0.95
            315                                                             480     4750/4530    0.95
            400              35          ±5                    Dyn11        580     5740/5470    0.85
            500             38.5      ±2×2.5%       0.4         Yyn0        680     6910/6580    0.85      6.5
            630                                                             830       7860       0.65
            800                                                             980       9400       0.65
            1000                                                            1150      11500      0.65
            1250                                                           1400      13900       0.60
            1600                                                           1690      16600       0.60
            2000                                                           1990       19700      0.55
            2500                                                           2360      23200       0.55
           注 1: 对于额定容量为 500kVA 及以下的变压器,表中斜线上方的负载损耗值适用于 Dyn11 联结组,斜线下方的负载损耗值适用于 Yyn0 连接组。
           Note 1: Rated capacity 500KVA and below transformer, the load loss above the oblique line in the table applies to Dyn11 or Yzn11; the load loss
           below the oblique line applies to Yyn0.

           Page 07
   11   12   13   14   15   16   17   18   19   20   21