Page 15 - 浙江中盛电力设备有限公司
P. 15

S11


         系列油浸式变压器
         Series of oil-immersed transformer


          S11 系列 10kV 级三相双绕组无励磁调压电力变压器
          S11 series 10kV three - phase dual - winding non - excitation voltage regulator power transformer

                                    电压组合及分接范围
                                                                                                       短路阻抗
           额定容量               Voltage Combinationand Tap range  联结组标号       空载损耗      负载损耗    空载电流    Short circuit
                                                                                              No-load
           Rated capacity   高压        高压分接范围           低压         Vector    No-load  Load loss  current  impedance
           (kVA)        High pressure  High pressure tap   Low pressure  Group Symbol  loss(W)  (W)  (%)  (%)
                            (kV)       range (% )     (kV)
           630                                                                820      6920     0.60
           800                                                               1000      8460     0.60
           1000                                                              1180      9910     0.60
                             6
                                                        3
           1250             6.3                        3.15                  1400     11700     0.50
           1600              10                        6.3                   1680     14100     0.40
                            10.5
           2000                         ±2×2.5                     Yd11      2010     16900     0.40     5.5
                                          ±5                      Dyn11
           2500                                                              2370     19600     0.40
           3150                                                              2800     23000     0.40
           4000                                                              3450     27300     0.40
                             10                        3.15
           5000                                                              4100     31300     0.40
                            10.5                       6.3
           6300                                                              4890     35000     0.40




          SZ11-M 系列 10kV 级三相双绕组有载调压配电变压器
          SZ11-M series 10kV three-phase double-winding on-load tap-changer distribution transformer

                                    电压组合及分接范围
                                                                                                       短路阻抗
           额定容量               Voltage Combinationand Tap range  联结组标号       空载损耗      负载损耗    空载电流    Short circuit
                                                                                              No-load
           Rated capacity   高压        高压分接范围           低压         Vector    No-load  Load loss  current  impedance
           (kVA)        High pressure  High pressure tap   Low pressure  Group Symbol  loss(W)  (W)  (%)  (%)
                            (kV)       range (% )     (kV)
           200                                                                380      2900     1.00
           250                                                                440      3420     0.90
           315                                                                530      4100     0.90     4.0
           400                                                                640      4950     0.80
           500                                                                760      5890     0.80
                             6
           630              6.3         ±4×2.5         0.4        Dyn11       960      7260     0.60
           800               10                                   Yyn0       1120      8890     0.60
                            10.5
           1000                                                              1360     10400     0.60     4.5
           1250                                                              1560     12300     0.50
           1600                                                              1920     14700     0.50
           2000                                                              2270     18600     0.40
                                                                                                         5.0
           2500                                                              2680     21600     0.4

          注 1: 对于额定容量为 500kVA 及以下的变压器,表中斜线上方的负载损耗值适用于 Dyn11 联结组,斜线下方的负载损耗值适用于 Yyn0 连接组。
          Note 1: Rated capacity 500KVA and below transformer, the load loss above the oblique line in the table applies to Dyn11 or Yzn11; the load loss  below the oblique line applies to Yyn0.