Page 13 - 通用电气(中国)有限公司
P. 13

EntelliGuard* L



 How to order   in eight simple steps




                  Step 5                    Step 6                 Step 7                 Step 8


          Finalize the basic catalogue   Basic catalogue number is  If universal internal  Full catalogue number defines
          number see catalogue pages:  a manually operated device  accessories are needed?  a Breaker without trip unit.
          A 4-A.6 - Fixed Pattern   If a Motor Operated device is   Options       (Isolators do not need trip units)
          A 4-A.6 - Drawout Portion  requested?            UVR or SHT release (s)  For all Breakers ADD
          A.5-A.7 - Connections fixed pat.  Please order   Auxiliary contacts     Trip Unit
          A 5-A.7 - Cassettes, drawout  Motor and closing coils as   Alarm & signal contacts
                                    Indicated here                                                                 How to order in eight simple steps





             Completing the basic           Add                     Add                    Add
              catalogue number        catalogue number (s)    catalogue number (s)   catalogue number (s)


                 No addition
          Breaker in fixed pattern equipped
                                                                If chosen device is
          with RearConnection (Horizontal**),   If chosen device is   a Breaker or Isolator  If chosen device is
                                                                                         a Breaker
          a set of 3NO/3NC aux.Contacts is   a Breaker or Isolator  See page A.9        See page A.8
                  included
                                           Envelope 1          To add 1 SHT and/or    Add one of Four Basic
                                          See page A.9           1 UVR release          Trip units types         Intro
          Other options include Rear(Vertcal)   Order a Motor Envelope 1   or two SHT releases.  Offering
            and Front (Flat) connections  and 1 Closing Coil
                                         Based on voltage                         An Extremely Large setting range
                                          Requirements                            covering Overload, Delayed and
          See page A 6 to order Field moun-  and specifications                   Instantaneous Short Circuit Pro-  A
              table Adaptation Kits                                                 tection and or Groundfault
               Field mountable                                  If chosen device is
                                        If chosen device is
              See pages A.4 & A.6       a Breaker or Isolator  a Breaker or Isolator
                                                                 See page A.9
                                           Envelope 2        To extend on the installed                            B
                                          See page A.9         3 NO + 3NC contacts
                 No addition          Order a Motor Envelope 2   Maximum of 4 possible
            Indicates Breaker / Isolator  and 1 Closing Coil
              Moving Portion Only        Based on voltage       If chosen device is                                C
             has set of 3NO/3NC aux.      Requirements         a Breaker or Isolator
               Contacts included        and specifications       See page A.9
              See pages A.4 & A.6                            To add Bell Alarm and/or
                                                              Ready to close contact
                                                                                                                   D
                                                                If chosen device is
                    U U                                           a Cassette
          = Cassette withUniversal ‘T stabs’                     See page A.9                                      E
           suited for use as Horizontal or                      If chosen device is
             Vertical rear connections                            a Cassette
                                                                 See page A.9
                    H
                    H
           = Cassette with Horizontal Rear                                                                         X
                Connections
                                                                   - Or -
                    V V
           = Cassette with Vertical Rear    A 2nd ordering method can be used in which the fully configured breaker or cassette is
                Connections          defined in one character string, This string comprises 18 digits when used for the breaker
            Vertical Rear Connections                  and 12 for when used for the cassette.
                    F F                          This global ordering code is referred to within GE as the :
            = Cassette with Front Flat                        Catalogue Number
                 connections        It can be defined with stand alone and freely available GE software , is used on all relevant
             Safety Shutters always   ordering documents and printed on each EntelliGuard breaker front facia. An explanation of
             Supplied with Cassette          this code and it’s use can be found on page A.28 of this catalogue.

               See page A.5 & A.7       When ordering with the method indicated here our CRC department will define and
                                                 confirm the mentioned individual Catalogue Number.

                                   Devices ordered here are supplied factory fitted.

                                    Remark : For Other Field Mountable Accessories see page A.11, A.12 & A.13




                                                                                                                A.3
   8   9   10   11   12   13   14   15   16   17   18