EntelliGuard* L
How to order in eight simple steps
Step 5 Step 6 Step 7 Step 8
Finalize the basic catalogue Basic catalogue number is If universal internal Full catalogue number defines
number see catalogue pages: a manually operated device accessories are needed? a Breaker without trip unit.
A 4-A.6 - Fixed Pattern If a Motor Operated device is Options (Isolators do not need trip units)
A 4-A.6 - Drawout Portion requested? UVR or SHT release (s) For all Breakers ADD
A.5-A.7 - Connections fixed pat. Please order Auxiliary contacts Trip Unit
A 5-A.7 - Cassettes, drawout Motor and closing coils as Alarm & signal contacts
Indicated here How to order in eight simple steps
Completing the basic Add Add Add
catalogue number catalogue number (s) catalogue number (s) catalogue number (s)
No addition
Breaker in fixed pattern equipped
If chosen device is
with RearConnection (Horizontal**), If chosen device is a Breaker or Isolator If chosen device is
a Breaker
a set of 3NO/3NC aux.Contacts is a Breaker or Isolator See page A.9 See page A.8
included
Envelope 1 To add 1 SHT and/or Add one of Four Basic
See page A.9 1 UVR release Trip units types Intro
Other options include Rear(Vertcal) Order a Motor Envelope 1 or two SHT releases. Offering
and Front (Flat) connections and 1 Closing Coil
Based on voltage An Extremely Large setting range
Requirements covering Overload, Delayed and
See page A 6 to order Field moun- and specifications Instantaneous Short Circuit Pro- A
table Adaptation Kits tection and or Groundfault
Field mountable If chosen device is
If chosen device is
See pages A.4 & A.6 a Breaker or Isolator a Breaker or Isolator
See page A.9
Envelope 2 To extend on the installed B
See page A.9 3 NO + 3NC contacts
No addition Order a Motor Envelope 2 Maximum of 4 possible
Indicates Breaker / Isolator and 1 Closing Coil
Moving Portion Only Based on voltage If chosen device is C
has set of 3NO/3NC aux. Requirements a Breaker or Isolator
Contacts included and specifications See page A.9
See pages A.4 & A.6 To add Bell Alarm and/or
Ready to close contact
D
If chosen device is
U U a Cassette
= Cassette withUniversal ‘T stabs’ See page A.9 E
suited for use as Horizontal or If chosen device is
Vertical rear connections a Cassette
See page A.9
H
H
= Cassette with Horizontal Rear X
Connections
- Or -
V V
= Cassette with Vertical Rear A 2nd ordering method can be used in which the fully configured breaker or cassette is
Connections defined in one character string, This string comprises 18 digits when used for the breaker
Vertical Rear Connections and 12 for when used for the cassette.
F F This global ordering code is referred to within GE as the :
= Cassette with Front Flat Catalogue Number
connections It can be defined with stand alone and freely available GE software , is used on all relevant
Safety Shutters always ordering documents and printed on each EntelliGuard breaker front facia. An explanation of
Supplied with Cassette this code and it’s use can be found on page A.28 of this catalogue.
See page A.5 & A.7 When ordering with the method indicated here our CRC department will define and
confirm the mentioned individual Catalogue Number.
Devices ordered here are supplied factory fitted.
Remark : For Other Field Mountable Accessories see page A.11, A.12 & A.13