Page 14 - Yueqing Dingqiao Electric Co., Ltd. (English)
P. 14

Characteristics and Performance
        TNSX MCCB from 16A to 250A





                                                          Common characteristics
                                                                  Insulation voltage (V)  Ui                800
                                                                  Insulation voltage for ELCB   Ui          500
                                                          Rated   Impulse withstand voltage (kV)  Uimp      8
                                                          voltages
                                                                  Operational voltage (V)  Ue  AC 50/60 Hz  690
                                                                  Operation voltage for ELCB  Ue  AC 50/60 Hz  440
                                                          Suitability for isolation            IEC/EN 60947-2  yes
                                                          Utilisation category                              A
                                                          Pollution degree                     IEC 60664-1  3


                                                          Circuit breakers                                                      TNSX100                            TNSX160                             TNSX250
                                                          Breaking capacity levels                                              B        F        N        H       B        F        N        H        B       F        N        H
        TNSX 100N/160N  3P
                                                          Electrical characteristics as per IEC/EN 60947-2
                                                          Rated current (A)   In      40 °C                                     100                                160                                 250
                                                          Number of poles                                                       2 , 3, 4                           2 , 3, 4                            2 , 3, 4
                                                          Breaking capacity (kA rms)
                                                                                                        220/240 V               40       85       90       100     40       85       90       100      40      85       90       100
                                                                                                         380/415 V              25       36       50       70      25       36       50       70       25      36       50       70
                                                                                                         440 V                  20       35       50       65      20       35       50       65       20      35       50       65
                                                                              lcu     AC 50/60 Hz
                                                                                                        500 V                   15       25       36       50      15       30       36       50       15      30       36       50
                                                                                                        525 V                   -        22       35       35      -        22       35       35       -       22       35       35
                                                                                                        660/690 V               -        8        10       10      -        8        10       10       -       8        10       10
                                                          Service breaking capacity (kA rms)
                                                                                                        220/240 V               40       85       90       100     40       85       90       100      40      85       90       100
                                                                                                        380/415 V               25       36       50       70      25       36       50       70       25      36       50       70
        TNSX 100N/160N  4P                                                                              440 V                   20       35       50       65      20       35       50       65       20      35       50       65
                                                                              lcs     AC 50/60 Hz
                                                                                                        500 V                   7        12       36       50      15       30       36       50       15      30       36       50
                                                                                                        525 V                   -        11       35       35      -        22       35       35       -       22       35       35
                                                                                                        660/690 V               -        4        10       10      -        8        10       10       -       8        10       10
                                                          Durability (C-O cycles)     Mechanical                                50000                              40000                               20000
                                                          Characteristics as per UL 508
                                                                                                        240 V                   -        85       85       85      -        85       85       85       -       85       85       85
                                                          Breaking capacity (kA rms)  AC 50/60 Hz       480 V                   -        25       50       65      -        35       50       65       -       35       35       35
                                                                                                        600 V                   -        10       10       10      -        10       10       10       -       15       15       15
                                                          Protection and measurements                                           ●                                  ●                                   ●
                                                          Short-circuit protection  Magnetic only                               ●                                  ●                                   ●
                                                                              Thermal magnetic                                  ●                                  ●                                   ●
                                                                                                                                ●                                  ●                                   ●
                                                                                      with neutral protection (Off-0.5-1-OSN)   ●                                  ●                                   ●
                                                                              Electronic
                                                                                      with ground-fault protection              ●                                  ●                                   ●
        TNSX 250N  3P                                                                 with zone selective interlocking (ZSI)    ●                                  ●                                   ●
                                                                                      By Vigi add-on                            ●                                  ●                                   ●
                                                          Earth-leakage protection
                                                                                      By Vigirex relay                          ●                                  ●                                   ●
                                                          Installation / connections
                                                          Dimensions and weights
                                                          Dimensions (mm)                               2/3P                    105 x 161 x 86                     105 x 161 x 86                      105 x 161 x 86
                                                          W x H x D                   Fixed, front connections   4P             140 x 161 x 86                     140 x 161 x 86                      140 x 161 x 86
                                                                                                        2/3P                    2.05                               2.2                                 2.4
                                                          Weight (kg)                 Fixed, front connections
                                                                                                         4P                     2.4                                2.6                                 2.8
                                                          Connections
                                                          Connection terminals        Pitch             With/without spreaders  35/45 mm                           35/45 mm                            35/45 mm
                                                          Large Cu or Al cables       Cross-section     mm²                     300                                300                                 300
                                                          Source-changeover system
        TNSX 250N  4P                                     Manual mechanical interlocking                                        ●                                  ●                                   ●
                                                          Automatic source-changeover                                           ●                                  ●                                   ●


        10
   9   10   11   12   13   14   15   16   17   18   19