Characteristics and Performance
                                                               TNSX MCCB from 16A to 250A





 circuit breakers  TNSX100                            TNSX160                                  TNSX250
 Number of poles  1                    2              1                        2               1
 toggle  ●                             ●              ●                        ●               ●
 manual
 Control  direct or extended rotary handle  -  -      -                        -               -
 electric  -                           -              -                        -               -
 front connection  ●                   ●              ●                        ●               ●
 fixed
 rear connection  ●                    ●              ●                        ●               ●
 Connections
 front connection  -                   -              -                        -               -
 withdrawable
 rear connection  -                    -              -                        -               -
 Electrical characteristics as per IEC/EN 60947-2
 Rated current (A)  In  40 °C  100     100            160                      160             250
 Rated insulation voltage (V)  Ui  750  750           750                      750             750
 Rated impulse withstand voltage kV)  Uimp  8  8      8                        8               8
 AC 50/60 Hz   277                     690            277                      690             277
 Rated operational voltage (V)  Ue
 DC      250                           500            250                      500             -
 Type of circuit breaker  F  N         F              F              N         F               N
 220/240 V  18          25             36             18             25        36              25
 380/415 V  -           -              18             -              -         18              -
 AC
 Ultimate breaking capacity (kA rms)  lcu  50/60  440 V  -  -  15  -  -        15              -
 Hz
 500/525 V  -           -              10             -              -         10              -
 660/690 V  -           -              5              -              -         5               -
 Service breaking capacity (kA rms)  lcs  % Icu  100 %  100 %  100 %           100 %           100 %
 Suitability for isolation  ●          ●              ●                        ●               ●
 Utilisation category  A               A              A                        A               A
 mechanical  20000                     20000          20000                    20000           10000
 Durability (C-O cycles)  In/2  20000  20000          20000                    20000           10000
 electrical  277 V
 In      10000                         10000          10000                    10000           5000
 Protection and measurements
 Type of trip units  built-in thermal-magnetic        built-in thermal-magnetic                built-in thermal-magnetic
 In      16 20 25 30 40                50 63 80 100   125 160                                  160 200 250
 Ratings  long time  Ir  fixed                        fixed                                    fixed
 Overload protection (thermal)
 threshold  16 20 25 30 40             50 63 80 100   125 160                                  160 200 250
 instantaneous       lm   fixed                       fixed                                    fixed
 Short-circuit protection (magnetic)
 pickup  value indicated for AC  190 190 300 300 500  500 500 640 800  1000 1250               850 850 850
 Vigi add-on  -                        -              -                        -               -
 Add-on earth-leakage protection
 combination with Vigirex relay  -     ●              -                        ●               -
 Additional indication and control auxiliaries
         -                             ●              -                        ●               -
 Indication contacts  MX shunt release   -            -                                        -
 Voltages releases                     ●                                       ●
 MN undervoltage release  -            ●              -                        ●               -
 Installation
 Accessories  terminal extensions and spreaders  ●  ●  ●                       ●               ●
 terminal shields and interphase barriers  ●  ●       ●                        ●               ●
 escutcheons  ●                        ●              ●                        ●               ●
 Dimensions (mm)  W x H x D  35 x 161 x 86  70 x 161 x 86  35 x 161 x 86       70 x 161 x 86   35 x 161 x 86
 Weight (kg)  0.7                      1.2            0.7                      1.2             0.7
 Source changeover system
 Manual mechanical interlocking  ●     ●              ●                        ●               ●