4V100• Series 4V200• Series
We make the difference ISO9001:2008
Solenoid• Valve,• Air• Pilot• Valve Solenoid• Valve,• Air• Piloted• Valve
Overall• Dimension
Valve Valve
DJF DJF
3V110-06
3V110-M5
JELMP 3V110-M5 3V110-06 JELMP
JELP/G JELP/G
MCS MCS
4V100 4V100
4V100
4V200 4V200
4V200
4V210-08
4V220-08
4A210-08
4V300 4A210-08 4V210-08 4V220-08 4V300
4V400 4V400
Manifold Manifold
SV SV
3V1 3V1
JEL JEL
3VJZF 3VJZF
4V210-08B
4V210-08
4V210-08B
4V210-08
4V230C-08
4V230C-08
4VJZF 4V210-08B 4V210-08 4V230C-08 4VJZF
MVSD MVSD
VF,• VZ VF,• VZ
BM Ordering• Code BM
Diaphragm 3V120-M5 3V120-06 Diaphragm
Coil 4V - 2 - 10 - 08 - B - AC220V - W - F Coil
2V 2V
2W 2W
2W(Big) Specification Series• Code Coil and Type Port• size Connection and Initial Status Standard• • Voltage Wiring Joint 2W(Big)
2P 4V: 5/2 (3) way solenoid valve 200• Series 10: Single coil 06: 1/8″ Blank:• Threaded DC12V• • • • • DC24V Blank:• • Without• light terminal 1• F-20• F•••• 2P
•
2L 4A: 5/2 (3) way air pilot valve 20: Double coil 08: 1/4″ B: Sub-plated mounted AC24V• • • • • 50Hz/60Hz LD: Brown with light terminal 2L
VX 3V: 3/2 way solenoid valve 30C: Mid-position closed (for 5/2,5/3 way only) AC110V• • • 50Hz/60Hz LD1: White with light terminal VX
PU 3A: 3/2 way air pilot valve 30E:• Mid-position exhausted NC: 3/2 way normal close AC220V• • • 50Hz/60Hz W: Lead wire PU
PU225 30P:• Mid-position• pressed NO: 3/2 way normal open • AC380V• • • 50Hz/60Hz PU225
2Q 2Q
JEL5404 JEL5404
JEL6213 JEL6213
BU BU
Pulse Specification Pulse
JEL.JZF JEL.JZF
4H 4V210-06 4V220-06 4V230C-06 4V230E-06 4V230P-06 4V210-08 4V220-08 4V230C-08 4V230E-08 4V230P-08 4H
TSV Model TSV
4A210-06 4A220-06 4A230C-06 4A230E-06 4A230P-06 4A210-08 4A220-08 4A230C-08 4A230E-08 4A230P-08
MPV MPV
Valve Type 5/2 way 5/3 way 5/2 way 5/3 way
4HV 3A110-M5 3A110-06 4HV
2
2
2
2
HV,• K Effective Cross Section Area 14• mm (CV=0.78) 12• mm (CV=0.67) 16• mm (CV=0.89) 12• mm (CV=0.67) HV,• K
4R Model 3V210-06 3V220-06 3A210-06 3A220-06 3V210-08 3V220-08 3A210-08 3A220-08 4R
FV Valve Type 3/2 way FV
MSV MSV
2•
2•
Effective Cross Section Area 14• mm (CV = 0.78) 16• mm (CV = 0.89)
JM JM
ASC,• RE Port• Size Inlet,• Outlet,• Exhaust Port = G 1/8″ Inlet,• Outlet= G 1/4″,• Exhaust Port = G 1/8″ ASC,• RE
QE,• QEA Working• Medium 40 Micron Filtered Air QE,• QEA
ST Operation Internal• piloted ST
HSV Working-pressure 0.15~0.8 MPa HSV
Max. Test Pressure 1.2• MPa
3A120-M5 3A120-06 Ambient Temperature 5~50 ℃
Operating Voltage Tolerance
Power Consumption AC:• 5.5• VA• • • • • DC:• 4.8• W
Connector Protection F• Class,• IP• 65
Wiring / Connector Cable / Lead Wire or DIN Connector
Switching Frequency 5 Cycles / Sec.
Response• Time 0.05 Sec.
2-|P 09 2-|P 10