Page 44 - 通用电气(中国)有限公司
P. 44

EntelliGuard* L



                  Time Current Curves (cold state)

                  GF Protection Device



                               EntelliGuard GT Electronic Trip Unit            EntelliGuard GT Electronic Trip Unit
                      10      LT set at Breaker Rating In  - Time Current Curve  10  LT set at Breaker Rating In  - Time Current Curve
                              Setting Range        GF- Protection Device      Setting Range                         GF- Protection Device

                               0,2 to 1 x In in steps of 0,01                  0,2 to 1 x In in steps of 0,01
                                   i   f            I t  “max.”-ON-                                  I t  “max.”-ON-
                                                  2
                                                                                                   2
                                                 -  Band GFDB 01                                  -  Band GFDB 02
                                                 -  Band GFDB 03                                  -  Band GFDB 04
                                                 -  Band GFDB 05                                  -  Band GFDB 06
                                                 -  Band GFDB 07
      Electronic Trip Units  0,8 1  13      13                         0,8 1  14            14
                                                                                                  -  Band GFDB 08
                                                 -  Band GFDB 09
                                                                                                  -  Band GFDB 10
                                                 -  Band GFDB 11
                                                                                                  -  Band GFDB 12
                                                 -  Band GFDB 13
                                                                                                  -  Band GFDB 14
                                                                                            12
                                                                              12
                                            11
                      0,6
                                                                       0,6
                              11
                                                                                            10
                                                                              10
                                            9
                      0,4
                                                                       0,4
                              9
                                                                                            8
                                            7
                                                                              8
                                                                                            6
                      0,2
                              3 7 5         5 3 1                      0,2    4 6           4 2
                      0,1                                             0,1
                                                                                                  Green line = Full Clearing time
                                                 Green line = Full Clearing time                  Red Line  = Non Tripping time
  Intro                       1                  Red Line  = Non Tripping time  2
    A                Tripping Time In Seconds (s)                    Tripping Time In Seconds (s)
    B                 0,01  1 , 0  0      0 , 1  0         1  0 , 0  0  0,01  1 , 0  0     0 , 1  0         1  0 , 0  0
                         x Breaker Rating In                             x Breaker Rating In
                                                               ]                                               ]
    C
                   Denonimation           Description
                     In       Current rating of Breaker
    D                Ir       Current setting
                     LT       Long Time or Overload protection
                     ST       Short Time or Timed Short circuit protection
                              Instantaneous Short circuit protection
                     I        (new IEC refererence I i  )
    E                GF       Groundfault
                     Ir       LT or overload Current setting
                              ST or Timed Short circuit Current setting
                     Ist
                              (new IEC refererence I SD   )
    X                Ii Ig    Instantaneous Short circuit Current setting
                              Ground, or Earthfault Current setting
                     LTDB     LT or overload time delay band
                              (new IEC refererence t r  )
                              ST or short circuit time delay band
                     STDB
                              (new IEC refererence t SD   )
                     I t 2    'Slope' setting on ST or GF device
                     I t 4    'Slope' setting on GF device
                     x LT     Multiple of LT or overload Current setting
                     x In     Multiple of Breaker Current rating
                     x CT     Multiple of installed sensor rating
                              (In IEC EntelliGuard types =In)
                     I        Standard Instantaneous
                     MCR      Making Current Release
                     HSIOC    Hi set Instantaneous protection.









     B.14